4.8. Soft-Reset
A softreset can be initiated at any time by writing the command softreset (0xB6) to register CMD. The
softreset performs a fundamental reset to the device which is largely equivalent to a power cycle.
Following a delay, all user configuration settings are overwritten with their default state (setting stored
in the NVM) wherever applicable. This command is functional in all operation modes but must not be
performed while NVM writing operation is in progress.