Interrupt engine overrun
The interrupt overrun ishall be asserted if filter and interrupt computations cannot be finished in a
sample acquisition time. The interrupt status is mapped (mirrored) to all interrupt registers INT_STAT0,
INT_STAT1 and INT_STAT2, bit ieng_overrun_stat. The interrupt is cleared by reading of any of these
registers.
The interrupt is mapped to pads INT1 and INT2 by the registers INT1_MAP.
ieng_overrun_int1 and INT2_MAP. ieng_overrun_int2.
The interrupt behavior is not dependent on non-latch, latch mode setting.