The timed timeout trigger can be configured by setting AUTOLOWPOW_1.auto_lp_timeout bits in
register according to the table below.
AUTOLOWPOW_1.auto_lp
_timeout<1:0>
Description
b00
timeout disabled, use either
AUTOLOWPOW_1.drdy or
AUTOLOWPOW_1.gen1_int to switch automatically into low-
power mode
b01
timeout active, BMA400 switching into low-power mode as soon
as timeout counter reaches
AUTOLOWPOW_1.auto_lp_timeout_thres
b10 or b11
Low-power timeout active, timeout counter resets on activity
detection
Multiple selections of auto-low-power conditions are supported. Any selected condition switches the
device into low-power mode (OR condition). The logical connection of the auto-low-power conditions
is shown in the picture below.