Datasheet

Page 120 /
Confidential
BST-BMA400-DS000-00 | Version 0.1 | November 2017 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.
BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Register (0x71) STEP_COUNTER_CONFIG24
DESCRIPTION: Reserved
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x71) STEP_COUNTER_CONFIG24
Bit
7
6
5
4
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
sccr24
Bit
3
2
1
0
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
sccr24
Register (0x7C) IF_CONF
DESCRIPTION: Serial interface settings
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x7C) IF_CONF
Bit
7
6
5
4
Read/Write
n/a
n/a
n/a
n/a
Reset Value
0
0
0
0
Content
reserved
Bit
3
2
1
0
Read/Write
n/a
n/a
n/a
RW
Reset Value
0
0
0
0
Content
reserved
spi3
spi3: Configure SPI Interface Mode for primary interface
spi3
0x00
spi4
SPI 4-wire mode
0x01
spi3
SPI 3-wire mode
Confidential and under NDA
Seeed Studio
Confidential and under NDA
Seeed Studio
Confidential and under NDA