Datasheet

Page 107 /
Confidential
BST-BMA400-DS000-00 | Version 0.1 | November 2017 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.
BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
tics_th
0x00
6
6 data samples for high-low tap signal change time
0x01
9
9 data samples for high-low tap signal change time
0x02
12
12 data samples for high-low tap signal change time
0x03
18
18 daata samples for high-low tap signal change time
quiet: Minimum quiet time before and after double tap, in data samples
This time also defines the longest time interval between two taps so that
they are considered as double tap
quiet
0x00
60
60 data samples quiet tie between single or doube taps
0x01
80
80 data samples quiet tie between single or doube taps
0x02
100
100 data samples quiet tie between single or doube taps
0x03
120
120 data samples quiet tie between single or doube taps
quiet_dt: Minimum time between the two taps of a double tap, in data samples
quiet_dt
0x00
4
4 data samples minimum time between double taps
0x01
8
8 data samples minimum time between double taps
0x02
12
12 data samples minimum time between double taps
0x03
16
16 data samples minimum time between double taps
Confidential and under NDA
Seeed Studio
Confidential and under NDA
Seeed Studio
Confidential and under NDA