Datasheet
Preliminary Data Sheet
BMA400
Page 106 /
Confidential
BST-BMA400-DS000-00 | Version 0.1 | November 2017 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.
BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Register (0x57) TAP_CONFIG
DESCRIPTION: tap interrupt configuration registers
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x57) TAP_CONFIG
Bit
7
6
5
4
Read/Write
n/a
n/a
n/a
RW
Reset Value
0
0
0
0
Content
reserved
sel_axis
Bit
3
2
1
0
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
sel_axis
tap_sensitivity
tap_sensitivity: sensitivity of the tap algorithm
0: highest sensitivity
7: lowest sensitivity
sel_axis: Modifies the selection of the data provided to the algorithm
sel_axis
0x00
Z
use Z axis data
0x01
Y
use Y axis data
0x02
X
use X axis data
Register (0x58) TAP_CONFIG1
DESCRIPTION: tap interrupt configuration registers
RESET: 0x06
DEFINITION (Go to register map):
Name
Register (0x58) TAP_CONFIG1
Bit
7
6
5
4
Read/Write
n/a
n/a
RW
RW
Reset Value
0
0
0
0
Content
reserved
quiet_dt
Bit
3
2
1
0
Read/Write
RW
RW
RW
RW
Reset Value
0
1
1
0
Content
quiet
tics_th
tics_th: Maximum time between upper and lower peak of a tap, in data samples
this time depends on the machanics of the device tapped onto
default = 12 samples
Confidential and under NDA