Datasheet
Preliminary Data Sheet
BMA400
Page 100 /
Confidential
BST-BMA400-DS000-00 | Version 0.1 | November 2017 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.
BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Register (0x4C) GEN2INT_CONFIG2
DESCRIPTION: the registers contain configurations for generic interrupt 1 evaluation
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x4C) GEN2INT_CONFIG2
Bit
7
6
5
4
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
gen2_int_thres
Bit
3
2
1
0
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
gen2_int_thres
gen2_int_thres: threshold configuration for interrupt detection: 8 mg/lsb
unsigned integer
Register (0x4D) GEN2INT_CONFIG3
DESCRIPTION: the registers contain configurations for generic interrupt 1 evaluation
RESET: 0x00
DEFINITION (Go to register map):
Name
Register (0x4D) GEN2INT_CONFIG3
Bit
7
6
5
4
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
gen2_int_dur_15_8
Bit
3
2
1
0
Read/Write
RW
RW
RW
RW
Reset Value
0
0
0
0
Content
gen2_int_dur_15_8
gen2_int_dur_15_8: duration for which the condition has to persist until interrupt can be triggered
duration is measured in data samples of selected data source
gen2_int_dur= 256*gen2_int_dur_15_8 + gen2_int_dur_7_0
Confidential and under NDA
Seeed Studio
Confidential and under NDA
Seeed Studio
Confidential and under NDA