User Manual
SEEDHAWK®TOOLBAROPERATOR’SMANUAL57
8.2 TROUBLESHOOTINGSCT®EQUIPPEDIMPLEMENTS
SYMPTOM
POSSIBLECAUSE
SOLUTION
Gateswillnot
open/close
Nohydraulicpressureto
meterblock
Engagehydrauliccircuit(wingdown)
CheckSCTnode Checklightson frontofnode
MeterblockPRV(pressure
reliefvalve)settolow
IncreasePRVpressureuntilgatescycle(donotexceed500psi)
Nopoweratcoils Turnmasterswitchon
Checkfuses
CheckconnectionsatcoilandSCTnode
Openerswillnot
lift
Nohydraulicpressureto
meterblock
Engagehydrauliccircuit(Opener)
BFJ(pressurereliefblock)
settolow
Increasepressure(factorysetto1800psi)
Nopoweratcoils Turnmasterswitchon
Checkfuses
Checkconnections
Wingdown
switchwillnot
work
Nohydraulicpressure Engagehydrauliccircuit(wingdown)
Masterswitchon Turnmasterswitchoff(unfoldonly)
Randomopener
sectionslifting
Improperlookaheads Ensurethatthelookaheadnumberisnotanegativenumber.
Agressivenesssettohigh Turnaggressivenessoff
Improperdrillsetup Checkdrillsetup
Meterroller
wontturn
Nohydraulicpressure Engagehydrauliccircuit(wingdown)
Productcontrolswitchis
off
Turnproductcontrolswitchtoauto
Rollerisjammed Removerollerfrommeterbodyandremoveobstructionfrom
meter.
Checkaircartnode Checklightsonfrontofnode
Checkmetersettings Makesurethatthemetercalandcalwieghtisentered
correctly
Nofanspeed Fansensoroutof
alignment
Checkandre‐alignsensorifnecessary.
Fancalisincorrect Setfancalto2
Nohydraulicpressure
Diverterblockissettothe
auger/conveyorposition
Setdivertertothefanposition
Notractor
speed
Speedsettingsset
incorrectly
Outeropener
sectionsengage
whenturning
Nofieldboundryrecorded Createafieldboundry
Agressivenessison Turnaggressivenessoff
Improperlookaheads Adjustlookaheadtime
Metergate
alarmsgoingoff
Proximitysensorsongates
misaligned
Alignproximitysensors
Gatesnotfunctioning See“gateswillnotopen/close”
Proximitysensordamaged Replaceproximitysensor