216 Seed Hawk® Viper Pro™ Installation & Operation Manual
Rx Map Issues
Coverage Map Issues
Issue Possible Cause Solution
Only one
prescription map
loads
A multi-product VRA
registration is not
available
• Purchase a multi-product registration from a local Raven dealer.
The prescription
map does not
display properly
Wrong datum type Use WGS-84 decimal degrees when creating an Rx map.
Issue Possible Cause Solution
Gaps displayed in
coverage map
Section widths not set
correctly
Check section widths and section center values.
Guidance and section
width not the same
Set guidance width and section width to the same value.
Product coverage
displayed in zero
rate zones
Vibration chatter in
encoder
Make sure that the encoder is firmly mounted. Increase value in
“Zero Rate Tolerance.”
Valve or motor is not set
to close completely
Adjust valve or motor to close or stop completely with no rate
applied.
Cannot achieve
target rate
• Driving too fast for
vehicle
• Speed may exceed capabilities of vehicle to deliver product.
Slow down the vehicle or configure the vehicle to supply a higher
amount of product.
• Calibration numbers
incorrect
• Check and adjust meter calibration, density, and other calibration
numbers.
• Speed calibration
incorrect
Check and adjust speed calibration setting.