9.6 METER SETTINGS
9.6.1 Meter Selection
Select which Meter you would like to view or make changes to.
Note: All Meters on a machine must be individually calibrated. Calibrations
must be done each time a crop is changed.
9.6.2 Pulses Per Rev
This is the number of pulses produced by
the meter sensor in one revolution. The
default setting is 80. If using a setup other
than a standard Seed Hawk configuration
this setting may need to be changed. To
change this setting use the up/down arrow
keys to highlight the line “Pulses Per Rev
80” and press the select button. “80” will
now be highlighted and can be changed
using the up/down arrow keys. Once the
desired value is on the screen press the
SELECT button again and the highlight bar
will move to the “Low Alarm Point” bar.