Owner's manual

SEED HAWK
®
2015 AIRCART OPERATOR’S MANUAL50
At the “Menu Settings” screen use the Navigation Keys or the Selector
Knob to place the highlight bar on "MuxBus Sensor Setup".
2. Plug in the sensors: Sensors
must be connected in the order listed
on the menu. Different sensors have
different types and cannot be learned
to the wrong location but the rst 
fan sensor plugged in will be assigned
to Fan 1.The rst bin level sensor 
plugged in will be learned to Bin 1, etc.
The speed, pressure, and ow sensors 
all use the same type sensor code so
the rst one plugged in will be the 
speed sensor, etc.
1. New system installation: Place the highlight bar on “Auto Detect” and
press the Soft Key labeled “Install.
7.4.1 MuxBus Sensor Settings and Installation
3. Add a sensor: Individual sensors
can be added to the MuxBus system
at any time. Place the highlight bar on
the sensor you want to add (Fan 1 in
the example) and press install. Then
plug in the sensor. Multiple sensors
can also be added using this method
but you need to position the highlight
bar on each new sensor and press
the Soft Key labeled “Install” before
plugging in each sensor.