Once a sample is collected (the larger the sample the more accurate the calibration) Select
“END”,thiswillstoptheroller.
Weighthefilledcalibrationbucket,entertheweightoftheproductcaught.Togglethe“LEFT”
and“RIGHT”keysmovingthearrowunderthedesireddigittoedit,select“ENTER”tomodify
thedigit.Togglebetween“INC”and“DEC”tochangethedigitvalue.
Oncetheweightisentered,toggletotheRIGHTuntil“SEND”appears.Select“SEND”tosave
thecalibrationnumbertotheViperPro™.Repeatthestepsfortheremainingmeters.
To turn off remote calibration console, press and hold the blue power button until the
monitorpowersdown.
NOTE:DONOTincludetheweightofthecalibrationbucketinthemeteredweightvalue.
InformationisinstantlysenttotheSeedHawkViperPro™monitor.
AfterallmetersarecalibratedPowerdowntheRemotetankcalibrationconsoleanddisconnect
fromtankharness.Itisrecommendedtorepeatthecalibrationtoavoidoperatorerror.
DO NOT leave the Remote tank calibration console attached to the tank
exposed to the
weather.REFER TO THE CALIBRATION GUIDE FOR ALTERNATIVE TIPS AND
RECOMMENDATIONSFORCALIBRATINGTHEAIRCARTMETERS.