Owner's manual

SEEDHAWK
®AIRCARTOPERATOR’SMANUAL73
Select“BEGIN”tostartthecalibrationprocess.
The meter needs to be primed before calibration begins to ensure full product flow during
calibration.Select“PRIMEMETERROLLER”toprimethemeter.
Pressthe“INC”buttontoincreasethePWMoutputthiswillincreasethespeedoftheroller.
Usethe“INC”and“DEC”buttonstoachievethedesiredrollerRPM.
ReferencetheRPMCharttogetanapproximat eRPMtherollerwillbeturningduringseeding.
Oncethemeterisprimed(atleast2revolutions)select“STOP”.Emptytheproduct caughtand
repositionthecalibrationbucketunderthemeter.
NOTE:ItisimportanttocalibrateasclosetotheactualseedingRPMoftheroller.Referencethe
“MeterRPMChart”togetanapproximaterollerRPMforthespecificrolleranddrillwidth.
Toggle to “START CALIBRATION” and select “ENTER”, this will cause the roller to turn at the
sameRPMassetinthePrimestep.