Owner's manual

SEEDHAWK
®AIRCARTOPERATOR’SMANUAL72
8.2.2 VIPERPRO™CALIBRATIONPROCEDURE
ATTENTION: Before a meter calibration can be done the implement width must be entered
andthespeed calibrationmustbecompleted(SeeSectionSetupWizardandCalculatingthe
speed Calibration sections of your Seed Hawk Viper Pro™ Manual).Exit to the Seed Hawk
Viper Pro Main Menu on the Viper monitor before powering up the Remote Calibration
Console.
NOTE:FOR CONVENIENT CALIBRATON, USE THE
REMOTE CALIBRATION CONSOLE THAT ATTACHES TO
THETANKHARNESS.
Tobegintheremotecalibrationofthemetersmountthe
remotecalibrationconsoleontheramballandattachthe
electrical connector.Turn the console on using the blue
powerbutton.
Afterturningontheremotecalibrationconsole,thebinselectionscreenisdisplayed.Usingthe
softkeysselect thebinwhichcorrespondstometertobecalibratedandselect“ENTER”.