8.1 FILTERANDPRESSUREREDUCINGVALVE
There is a filter placed in‐line with the hydraulic motors which is located at the front of the
aircartnearthedivertervalvefortheaugerorconveyor.Thefilterisequippedwithablockage
indicatorwhich displaysa red band when apressure differential greater than 5 bar (72.5 psi)
occurs.Note that low oil temperatures may give false blockage indication.To reset the
blockageindicatorpresstheplasticcoveratthetopof theindicator.Thefiltercartridge(part
number 317885) should be replaced first after 50 hours then yearly or when signified by the
blockageindicator.
Figure31
In addition to the filter there is a pressure reducing valve (PRV) which is located next to the
filter.This PRV is used to lower the hydraulic pressure entering the motors to 1500 psi.To
adjustthePRVloosenthenutat thetopofthePRV.Thenusinganallen
key,adjustthescrew
untilthegaugereads1500psi.TightenthenutatthetopofthePRV.