Owner's manual

SEEDHAWK
®AIRCARTOPERATOR’SMANUAL68
8.0 HYDRAULICDRIVE
All aircarts equipped with the Raven Viper Pro™ monitoring system have hydraulically driven
meters.These motors have a maximum sp eed of 113 RPM and a minimum speed of 2 RPM.
Speeds in excess of the maximum may result in premature wear or failure of the motors.
Reducingtherotationalspeedsof
themotorbelow2RPMmayresultinerraticmeteringwhich
mayaffecttheseedingrate.
Each hydraulic motor requires a flow rate of 1.0 gallons per minute.The maximum torque
outputis26ftlbs.Themaximuminletpressureofthehydraulicmotorsis1500psi.Theinlet
pressureisregulatedbyapressurereducingvalveasmentionedinsection8.1.
Rollerchangingprocedure:
NOTE:Ifthetankscontainproductensuretoshutthegatesbeforechangingthemeterroller.
1. Remove the two flange nuts holding
the hydraulic motor mount to the
meter body, the lynch pin on the
roller shaft and the hydraulic motor
spacer,Figure30.
2. Slidethe hydraulic motor and
hydraulic motor mount off of the
roller,Figure31.

Figure30
Figure31