5.2 General Electrical Specification
Nominal Power Supply: 12 Vdc
Supply Current: 3A or less, depending on the number and type of
sensors attached.
Fusing: The unit is protected with a polyswitch, which acts like a
resetting 3.75 A fuse
Power Supply Range: 10.5 to 16 Vdc
Overvoltage protection: Survive 24 Vdc for up to five minutes.
Transient Protection: The monitor and the attached sensors, when properly
installed, will not be damaged by the transients present
in the mobile agricultural environment (per ASAE EP455
5.11 and 5.12).
Power connection: 2-pin Packard WeatherPak
A - +12 Vdc
B - GND
Signal connection: 3-pin Packard WeatherPak
A - +12 Vdc
B - GND
C - Data
Radar Connection: AMP CPC connector
1 - GND
2 - Radar signal
3 - +12 Vdc to RADAR
4 - Radar present