4.24.10 TROUBLESHOOTING
1.MUXSensorisnotrecognizedatpowerup.Thiswillincludethegroundspeed,fan,andbin
levelsensors
Possible causes: Harness wiring is faulty or the sen sor is
defective.
Solution: With the system turned on, go the sensor that is
not communicating. There is a LED on each sensor (except
themultilevelbinsensor).Ifitisflashingslowly(1flashevery
2‐3 seconds) that indicates that power and groun d are
connected butthesensorwireisnot. Thepowerwire is+12
volts and is the white wire. It is in the “A” position on the
connector.TheGroundwireisblackandisinthe“B”position
ontheconnector.Thesensorwireisthegreenwireandisin
the“C” position on theconnector. If theLED is notflashing,
unplugthesensorfromtheharnessandplugitbackin.Ifthe
LED lights momentarily, power is present and the sensor is
faulty. If the LED does not light at all check power at the
connector. The user should measure 12 volts between the
white and black wire. If so, the sensor is faulty, if not, the
harnessisfaulty.AllthewhitewiresontheMUXharnessare
connected in parallel, all the black wires are in parallel, and
allthegreenwiresareinparallel.Youcanmeasurecontinuity
be‐ tween any of the “A”, “B”, or “C” connections on the
MUXharness.
+12VWHITE–A
BLACK–B
GREEN–C
FIGURE4.103
FIGURE4.102
FIGURE4.104
FIGURE4.103