User guide

SEEDHAWK®30SERIESOPERATOR’SMANUAL72
4.24.1 ENGAGEDRIVE
Themonitorrequiresseveralpiecesofinformationforfieldoperation.
1.TheremustbeanImplementwidthentered.
2.Theremustbeameterapplicationrateentered.
3.Theremustbeametercalibrationrateentered.
4.Forwardtravelspeedmustbepresent
5.Thedrivemustbeengaged.
Toengagethedrivepressthe“ACK”button.Thedriveiconintheuppercenterportionofthe
screen will turn solid. Engaging the drive will cause the furrow openers to lower to seeding
positionandwithtravelspeedpresenttheratemeterswillbegintoturn.
NOTE:Theusermust
havethefansinoperationbeforeengagingthedrive.Ifthefansarenot
operatingnormally,analarmscreenwillshowthatcannotbeacknowledged.
4.24.2 DISENGAGEDRIVE
At the end of a seeding pass, Press the “ACK”
buttonagain todisengagethemeterdrive.Thiswill
stop the application rate meters and raise the
furrow openers. This will stop the acre
accumulationregisteraswell.
FIGURE4.82
FIGURE4.83