User guide
SEEDHAWK®30SERIESOPERATOR’SMANUAL68
4.22.4 CLEARFIELDACRES
Choosing this item allows the user to clear the accumulated field acres.A dialog box will
appearverifyingtheselection.Onceverifiedthefieldacrescannotberestored.
NOTE:Total acres cannot be cleared fromthe settings menu. Contact your SeedhawkDealer
forinformationonclearingthetotalacresregister.
4.22.5 RATECONTROLLERMETERSETUP
This selection allows the operator to enter setup
informationfor the meters. The default screen is
meter1.Othermeterscanbeselectedbypressing
thesoftkeyforthedesiredmeter.
1. Pulses per Rev: This is the number of pulses
generated by the meter sensor equal to 1
revolutionofthemeterroller.Thisvalueissetby
defaultbutcan be manuallyentered.Thedefault
valueforaFenix2is10.00pulses/rev.
2.Lowalarmpoint:Thisistheminimummeterrpmspeedthemetercanturnbeforethe“low
meterrpm”or“meterstopped”alarms
willdisplay.Thedefaultvalueis0.5RPM.
3. Weight/Rev: This value is determined by the Meter calibration procedure or it can be
manuallyentered.
4.Increment:Thisvalueistheincrementvalueforonthegorateadjustmentswhenseeding.
Thedefaultvalueis5.00lb/ac.
5. OK/Cancel: Select “OK” to save any changes made. Select “Cancel” to ignore any change s
made.
FIGURE4.74
FIGURE4.75