User guide

SEEDHAWK®30SERIESOPERATOR’SMANUAL63
4.21 GROUNDSPEEDCALIBRATION
Allnewsystemsrequireagroundspeedcalibrationtoensureaccurateareatotalsandaccurate
groundspeedreadings.
NOTE:Duringthecalibrationthemonitoriscounting
the number of pulses produced from the drill
mountedsensor.Themonitorwilldisplaythepulses
counted in 400 feet. Choosing this item will allow
youtocalibratethegroundspeedsensortoaknown
distance. The default distance is 400 feet (122
meters)butthiscanbesetbytheuser.Toperforma
groundspeed calibration,determinethedistance to
beusedandmeasureoutacourse.
Procedure:
1.Tocompletethecalibration,measureacourse400
feet (122 meters) long preferably on level ground
with a start and finish point.Line up tractor at the
Start Point.The drill must be in the down position
throughouttheprocedure.
2.Onthemonitor,verifythatthecalibrationlengthis
400feet(122meters).Ifnot,pleasechangesothatit
reads400feet(122meters).
3.Once400feet(122meters)isselected,highlightandselectContinue.
4. The monitor now displays “Start Driving” and
shows a WheelPulses Received window.Noticethis
number increase while driving the 400 foot (122
meter)course.
5. Once at the end of the 400 foot (122 meter)
course, stop the tractor, highlight the complete
buttonandpressEnter.
6.GroundSpeedisnowcalibrated.
FIGURE4.61
FIGURE4.62
FIGURE4.63