User guide

SEEDHAWK®30SERIESOPERATOR’SMANUAL57
12. Remove all sensors:This menu choice allows
the user to quickly unlearn all MuxBus sensors
installedon the syst em. This is anecessary step if
it becomes ne cessary to relearn the MuxBus
systemonamonitorthatsensorsinstalled.
4.18.1 MUXBUSSENSORSETTINGSANDINSTALLATION
At the “MenuSettings”screen usethe navigationkeys orthe spinnerdialplace the highlight
bar on item 1 “MuxBus Sensor Setup”. Select this item by pressing the spinner dial or the
“Enter”key.
1.Newsysteminstallation:Placethehighlightbaron“AutoDetect”.Press“Install.
2.Pluginthesensors:intheorderlistedonthemenu.Differentsensorshavedifferenttypes
andcannotbelearnedtothewronglocationbutthefirstfansensorpluggedinwillbeassigned
toFan1.ThefirstBinLevelsen sorpluggedinwillbelearnedtoBin
1,etc.Thespeed,pressure,
andflowsensorsallusethesametypesensorcodesothefirstonepluggedinwillbethespeed
sensor,etc.
FIGURE4.45