User guide
SEEDHAWK®30SERIESOPERATOR’SMANUAL108
SYMPTOM
POSSIBLECAUSE
SOLUTION
Winghydraulicsystem
doesnotmaintain
pressure.
The“IN”pressuregaugeindicates
lessthan1200PSI
Inspectquickcouplerstoensurecomplete
engagement.
Check7plexwingdownvalue.(only
on7plexmachines.72feetandup)
Remove,inspecto‐rings,cleanandreplace
cartridgeifnecessary.
Wingliftcylinderpistonleaking. Removehosefromrodendof cylinder.Ifoil
discharges,sealisleaking.Removeand
replaceseal.
Wingsdonotrise. The“IN”pressuregaugeindicates
lessthan1200PSIforsmaller
implementsandlessthan2100PSI
forlargerimplements.
Inspectquickcouplerstoensurecomplete
engagement.Checktoseethatthecircuitis
puttingoutenoughpressure.
Wingcylinderpistonsealleaking. Removehosefromrodendofcylinder.Ifoil
discharges,sealisleaking.Removeand
replaceseal.
Cannotmaintain
packingpressureor
shankswillnotstayup
intransport.
Sealdamagedinshankcylinder.
Checko‐ringsonmeterengage
valvealsomakesuremeterengage
switchisshutoff.
Pressureshanksupandkeeplockedon.Undo
mainbridlehosesontherodendofcylinder
on
bothports.Ifoilisflowingoutofahose,
thenitisthatrankonthatwingthathasa
sealleak.Movedownthatrank,undoingthe
hosesontherodendofeachcylinder.When
theoilquitsflowing,itisthepreviouscylinder
withthefaulty
seal.Replacecylinderseal(s)
andrepeatprocessincaseofmorethanone
faultyseal.