Instruction Manual

SEED HAWK
®
2015 30 SERIES OPERATOR’S MANUAL – DOMESTIC52
5.7 Normal Operation
Once acknowledged, the audible alarm will cease and an icon of a bell at the
top of the display will ash.Also, an icon associated with the specic alarm 
will blink. For example if the BIn Level Alarm for Bin 1 becomes active and is
acknowledged, the Bin 1 icon will ash along with the alarm bell icon. If Bin 2 
then shows an alarm condition then the audible alarm will sound again. Once
acknowledged, the Bin 1 and Bin 2 icons will ash along with the alarm bell icon.
Low and High fan speed alarms can’t be acknowledged. The alarm condition
must be corrected to clear the screen of the alarm warning and to quiet the
audible alarm. If this alarm is going off in error, check the high and low alarm
point settings by going to the sensor conguration menu, highlighting the sensor 
in question and pressing the Soft Key labeled “Settings.
If all the installed sensors are found, the monitor will display a list of found sen-
sors. By pressing the Soft Key labeled “OK,” the operator can then access the
normal run screen. Items displayed on the run screen can be user selected and
the layout of the run screen can also be user selected, refer to Section 7.3.4. At
this point the system is ready for operation.
To power up, turn the monitor and press the Power Key. The monitor will go
through a short start up procedure and will display a list of all the sensors that
it recognizes from the installed system. If a sensor that should be present on
the system is not found a warning screen will display, Prompting the operator to
either ignore the sensor or to attempt to nd the sensor again.  
If multiple sensors are not found there will be multiple warning screens dis-
played with the rst expected sensor not found showing the rst warning 
screen. This will follow the order of the sensor installation screen. See trouble
shooting guide for possible reasons that a sensor or sensors are not found at
start up.