Instruction Manual
SEED HAWK
®
2015 30 SERIES OPERATOR’S MANUAL – DOMESTIC 41
At the “Menu Settings” screen use the Navigation Keys or the Selector
Knob to place the highlight bar on item "MuxBus Sensor Setup."
1. New system installation: Place the highlight bar on “Auto Detect” and
press the Soft Key labeled “Install”.
5.4.1 MUXBUS Sensor Settings and Installation
2. Plug in the sensors: Sensors
must be connected in the order listed
on the menu. Different sensors have
different types and cannot be learned
to the wrong location but the rst
fan sensor plugged in will be assigned
to Fan 1. The rst bin level sensor
plugged in will be learned to Bin 1, etc.
The speed, pressure, and ow sensors
all use the same type sensor code so
the rst one plugged in will be the
speed sensor, etc.
3. Add a sensor: Individual sensors
can be added to the MuxBus system
at any time. Place the highlight bar on
the sensor you want to add (Fan 1 in
the example) and press install. Then
plug in the sensor. Multiple sensors
can also be added using this method
but you need to position the highlight
bar on each new sensor and press
the Soft Key labeled “Install” before
plugging in each sensor.