User Manual
Care & use/ FIre PIT InsTallaTIon
|
9
LIGHTING INSTRUCTIONS
STEP 1: Make sure the gas shut-off valve on the LP Tank is in the open position
STEP 2: Start the spark igniter by pressing the ignition button. The starter will stay on until the button is pressed again.
STEP 3: Using the Gas Valve Key, open the gas burner control
valve through the opening in the control panel. Turn the key to the
left (counter-clockwise) until it is full open. The burner should light
immediately. If the burner does not light in 4 seconds, turn the gas valve
OFF, push the ignition button to turn off the igniter, Wait 5-minutes for
any gas to dissipate, then repeat steps 2 and 3 again. If the burner fails
to light contact Lynx Customer Care.
STEP 4: After the burner lights push in the ignition button to shut off
the ignition module.
STEP 5: Use the gas valve key to adjust the flame to a comfortable level.
DO NOT LEAVE A LIT FIRE-PIT UNATTENDED!
Shutting Down the Fire Pit
STEP 1: Using the Gas Valve Key Turn off the gas to the burner by turning the Key to the right (clockwise) until the
valve is fully closed
STEP 2: Shut OFF the LP tank gas valve
Converting to a Beverage Holder
You new Lynx Fire Pit is easily converted into an icy beverage holder for those warm days when a fire pit Is not needed.
STEP 1: Shut off gas from the LP Cylinder and remove the LP Hose
STEP 2: Disconnect the ignition wire at the connector
STEP 3: Lift out the burner pan using the convenient handle
STEP 4: Insert the Ice pan into the cutout opening
STEP 5: Fill with ice and your favorite beverages and enjoy.
Trouble ShooTing
1. Make sure a fresh 9 volt battery has been installed
2. Make sure all wire connectors are firmly attached. They may have come loose in shipping
3. Check to see that the LP tank is full and properly connected.
If you have any problems or concerns, please contact Lynx Customer care
Lynx Grills, Inc.
7300 Flores Street
Downey, CA 90242
888-289-5969