4. BATTERY CHANGE 
1  Press lid and remove it 
2  Take old batteries out 
(2 AAA dry cells) 
3  Insert new batteries 
(2 AAA dry cells) 
4  Insert lid again 
NOTE 
  Don’t mix new and used batteries 
  Remove batteries when unit is not be used for a longer time 
  The batteries hold for appx. one year under usual conditions 
  The remote control should be 1 m away from television or audio device, since it could 
interact under unfavorable conditions with them 
  Displace batteries correctly. They are not standard household waste. 
USER NOTES 
  The entire capacity of the indoor unit shall not exceed the capacity of the outdoor unit by 
150% over a longer time. Otherwise it will reduce the overall capacity 
  A breaker(Fuse) needs to be installed for each indoor unit and the capacity has to be 
according to the indoor unit’s electrical parameters. All indoor units are required to be 
centrally controlled by one switch, which enables to cut off electrical power in case of an 
emergency. The breakers act as short circuit prevention and to avoid abnormal overloads 
  The main switch must be accessible easily and at all times 
  Switch of power before cleaning and maintenance of the indoor units 
  After having turned off the indoor units, they will continue to work for 20-70 sec. to deplete 
the residual cool/heat in the unit’s evaporator, while preparing for next operation. This is 
normal 
  When the selected mode for the indoor unit does not correspond to the mode of the outdoor 
unit, the malfunction light will blink on the indoor unit or remote control. Change the 
operation mode or the indoor unit will stop after 5 sec without entry. The cooling mode is 
compatible with the Dry mode and the Fan mode is compatible with all modes. 
5.  HOW TO OPERATE THE UNIT 
1  Connect the unit with power and set eventual breaker on. The unit starts. Note: When unit is 
powered off, the guide louver of the indoor unit will close 
2  When you press the ON/OFF button, the Power/Run indicator switches over to green and 
shows the running mode (Cool, Heat, Auto). The air conditioner starts now to run. 
3  Press the MODE button to switch between the various running modes. 
4  Press the SWING button to start or stop the automatic swing mode of the indoor units 
5  Press the FAN button to set the desired fan speed. 
6  Press the + or - button to set the desired room temperature. 
7  Press the SLEEP button to set the unit to sleep 
8  Press the TIMER button to set a predefined start and Stop time, for example when you are 
not around and want to get it started half an hour before you return  
9  Press + and - simultaneously and you may lock or unlock the remote control. A lock sign 
appears in the display 
10  Switch unit off. Then press Mode and - simultaneously and you may switch between °F or °C 