User manual

Security & Electronic Technologies GmbH Seite 15
temperature switching function is active
Relay switches ON if the temperature falls below a limit
of e.g. 15°C.
Off: +0C
Relay and beeper switches OFF again if the
temperature rises above a limit of e.g. 17°C
(hysteresis).
7.
Relay2
For entries for Relay2, refer to 6.Relay1
8. Exit
Back to display mode
9.
Offset
ESC
Calibrat
Default
Zero point adjustment (probe offset)is indicated only
after a calibration has been performed
10.
Set h
xxxx
mm
Possibility to enter reference height for 2-point-
measurement, for a different probe measuring range,
or if density is unknown. Deduct 10 mm from the
current fill level as measured*, and enter the resulting
value. If tank height “5. Height” has been indicated in
cm (e.g. for probe measuring range from 1,000 mbar),
the value will be indicated in cm here!
Cal: No
Cal: Yes
If activated (Yes), a confirmation dialog follows
because from now on, the system will not calculate
with the density as entered but with a special factor.
Then, “Cal Mode” is indicated in step 1+2. If this entry
is made while the tank is almost empty, it is advisable
to perform a readjustment later on, see 11.Set V.
11.
Set V
xxx.xxxL
Readjustment of the fill level indication with +/- key.
Cal: No
Cal: Yes
See 10.Set h
12.
Unit
Unit:
m3Unit:
%Unit:
m
Default setting (3 decimal points: 999,900L)
(2 decimal points: 75.50 m3 )
(2 decimal points: 99.50 % )
(2 decimal points: 2.50 m )
13.
Round
Auto
Off
2, 5, 10,
20, 50,
100
Default setting (increments of 1). In dependence on the
preset volume, one or two zeros are added. This is to
say that a selected rounding value 2..100 refers to the
4
th
indicated position (e.g. for a 100.000L tank, 10=
stands for 1.000L rounding)
14. 19.
Exit
Back to display mode
20. LCD
Contr 52
Set the contrast of the LC-display
21. Info
Shows the following: