User manual

Page 14 Security & Electronic Technologies GmbH
Convex
Plastic battery tanks,
convex, slightly bellied
shape, alternative to
linear
Concav
e
Plastic battery tanks,
concave, slightly caved-
in shape, alternative to
linear
Plastics
Plastic tank with recess.
Plastic tank with a large
recess (hollow) in the
centre (without tape
bindings)
Cyl.>50
large cylindrical outdoor
tank 50.000 litres to
100.000 litres; a special
bearing chart conversion
table can be ordered
specifically for large
cylindrical tanks of 50 m³
to 100 m³.
4.
Volume
tank
volume
xxx.xxxL
Default setting is 0L. 0L is an invalid value.
This parameter must be set in all cases.
5.
Height
Inner
tank
height
x.xxx
mm
(or cm)
Default setting is 2.000 mm (the maximum value is
9.999 mm) - for probes from 1.000 mbar, the height is
indicated/set in cm, not in mm.
6.
Relay1
deactive
active
Default setting (enter on deactive go to next entry
step). Enter on active results in the next „On‟ step
On:
10%
10% is the default setting, range is 0..99
Relay and beeper switches ON if the content of the
tank falls below a limit of e.g. 10%.
Off:12%
12% is the default setting (hysteresis)
Relay and beeper switches OFF again if the content of
the tank rises above a limit of e.g. 12%. If On=0% and
Off=0%, no fill level switching function is active.
On: +0C
Only if a temperature adapter is available; range is
-99C .. +99C When On=0C and Off=0C, no