Instructions

Version 04-2017
Setup and Operation
P. 13
For device type NET / QUATTRO NET:
Info/Error-Messages at network communication
Error N 1
No network communication. A problem at the internal network module.
The device automatically executes a ’Reset’ for the internal network module
and retrys initial communications.
Try disconnection of network plug, wait… and remount the network plug.
Error N 2
Error at the network communication. Check the connections at the device
and at the network router...
Check parameter setup at menu item ‘15.Network’...
Check the function ’15.Network > Test > Ping: Yes’ …
Try to connect another network device at this network cable, e.g. a Laptop.
If it does not work please contact your network admin.
Important: The destination adress must be a fixed IP address.
Otherwise the device retries sending again and again.
If ‘Sending...’ is displayed periodically it is caused by an
unreachable IP address destination.
Sending ...
’Sending’ is shown in the display in case of current sending of a data message.
The message destination can be setup as an IP address at menu item
‘15.Network => Dest. ...’
If ‘Sending...’ is displayed periodically it is caused by an unreachable IP address
destination. The destination should be a fixed IP address. IP + Port should be setup
in correct manner.
XML-Data:
Call the device with command ip-address / xml via browser or program.
Remote controlling of the relay:
The NET device supports a remote control function for the relay.
The output relay can be operated by remote commands from a browser at the ‘CONFIG’ page
of the NET device.
Deactive = No switching
Active = State depends on level.
On = Makes the relay operate (fix).
Off = Makes the relay release (fix).