Set the VersaProbe COM Port on the Handheld
1. Access the main menu in the ORION Field Application software on the handheld. If you need help, go to "Program
Startup and Exit" onpage9.
2. Select Settings> Hardware Options to set the COM port for the VersaProbe. For additional information, see
"VersaProbe Touch Pad Reads" onpage19.
3. Tap Back twice to close the Settings screens and return to the main menu.
Initializing the VersaProbe Bluetooth Connection with the Handheld
MPORTANTI
Do not access the ORION Field Application software on the handheld until you perform steps 1 and 2.
1. Squeeze and hold the VersaProbe trigger.
2. When the message "RELEASE BUTTON NOW TO CONNECT" is displayed, release the trigger.
Result: The Bluetooth connection will initialize and you will hear a “ticking" sound.
3. Access the ORION Field Application software on the handheld. The ticking stops shortly after accessing Read Route.
OTE:N If there is no touch account in the route, the ticking does not stop.
4. Perform the read normally.
Terminating the VersaProbe Bluetooth Connection
1. When you nish reading, exit the ORION Field Application software.
2. The Bluetooth Connection may disable automatically. If the VersaProbe begins ticking, press and release the trigger
to disable the connection.
Result: The display conrms the Bluetooth connection has ended, then goes blank.
USING VERSAPROBE WITH BLUETOOTH
Page 95 October 2014 ORION® Field Application 4.0 for Trimble® Ranger 3 with ReadCenter®