User manual
Performing a VersaProbe Quick Read
To perform a Quick Read using the VersaProbe, follow these steps.
OTE:N Before performing a VersaProbe Quick Read, the VersaProbe battery must be charged and the COM port settings
must be configured. See "VersaProbe Touch Pad Reads" onpage19 for additional information.
1. Tap VersaProbe Quick Read on the ORION Field
Application main menu.
Result: The VersaProbe screen opens as shown in
Figure 91.
Figure 91: VersaProbe Quick Read screen
2. Align the end of the VersaProbe with the touch pad.
Then squeeze and release the trigger to capture the
reading.
Result: The reading is displayed, along with the date
and time of the last read, as shown in Figure 92.
Multiple reads can be captured by repeating step 2.
• Save: Tap to save the reading on the handheld.
To see the file, go to File Explorer> My Device>
Application Data> My Documents> ORION.
• Clear: Tap to clear the readings on the screen.
Figure 92: Quick Read completed
3. Tap Back to return to the ORION Field Application main menu.
VERSA PROBE QUICK READ
Page 48 October 2014ORION® Field Application 4.0 for Trimble® Ranger 3 with ReadCenter®