Use and Care Manual
23
activate a security video recorder. Activation devices or switches are sold as “Normally
Open” (N.O.) or “Normally Closed” (N.C.). A Normally Open switch is similar to a typical
light switch in your house. When the switch is OFF (or OPEN) no electricity flows to the
connected light fixture. When the switch is turned ON (CLOSED) the circuit is completed.
Please note the type of switch you are using as it will make a difference in the menu
settings.
Item Description
Alarm Duration(Seconds)
Alarm duration time (1~60 seconds). Sets the length of a recording
after a trigger is detected.
Sensor Popup Check the box to Enable/Disable the popup screen function for all
channels. When a sensor is activated during LIVE view mode, the
detected channel’s image will be shown in full screen display.
Sensor Polarity Click or press ▼ to select between Off, Low, and High voltage polarity for
each channel
Low Polarity:For connecting Normally Open devices. DVR will trigger
when the circuit is closed.
High Polarity: For connecting Normally Closed devices. DVR will trigger
when the circuit is opened.
Off
:
Alarm Input is deactivated.
All Off
Sets all alarm inputs to OFF.
All Low
All alarm inputs set to operate with Normally Open devices.
All High
All alarm inputs set to operate with Normally Closed devices.
3.4 Schedule Setup
Schedule Setup allows you to control when your DVR records including: normal, motion