Specifications
Page26of30
Loop installation:
• Barrier installations which close automatically utilize induction loops, to detect approaching vehicles.
• The loop should be laid symmetrically with respect to the boom. When determining the layout of the
loop, it should be remembered that the boom is fixed to the barrier housing at one side.
• The detection loop should be situated so that there is a distance of at least 500mm behind, and in
front of the boom. In special cases it is possible to deviate from this value by agreement with the
factory if a smaller detection area is required.
• The distance from the barrier housing and the end of the boom should be approx. 300 mm from the
induction loop.
• When concreting in or laying the loop, it should be ensured that the loop cannot move while in
operation. Any geometrical changes, causing result in inductance changes, causing interference to
the detector.
(c) Safety Measures:
The following safety instructions and country specific accident prevention regulations are to be
observed for installing and operating boom-barriers.
• The concrete foundation must be produced by the vendor as per the requirement.
• The minimum required distance between the end of the boom barrier and the nearest building
should be 500mm.
• The vendor must fit all permanent barrier installations with an all pole main switch which can be
locked up.
• The closing and opening actions must be observed. The mounting of operating elements outside the
field of view is not permissible; there must be a line of visibility between the barrier and the control
system.
• It is forbidden for persons or goods to be anywhere within the swing zone of the barrier boom while it
is in operation.
• The boom-barrier fixture can withstand winds of upto a maximum of force 10 on the Beaufort scale
(= 500N/m²).
(VII) Electro-Mechanical Turnstile ;
• The outer structure of the turnstile should be made of AISI304 scotch-brite finished stainless steel
with a removable cover.
• The tripod arm of the turnstile should be made of stainless steel with locking device preventing the
arm from being removed without appropriate tools.
• The turnstile should be designed to integrate the access control units.
• The turnstile should be equipped with an adjustable hydraulic cushion, programmable control logic
and an automatic release function for the tripod during blackouts.
• The turnstile should operate in 5 different modes:
- Access permanently free
- Access permanently mechanically locked
- Access mechanically locked with automatic unlocking device to give free passage in case of
power failure.
- Electrically controlled access
- Access electrically controlled with automatic unlocking device to give free passage in case of
power failure.
• The lateral casings should be made of AISI304 stainless steel, they are removable for easy
installation and wiring purposes.
• Power supply: 230V AC
• Protection rating: IP 40
• Operating temperature: -20°C to +55°C