Installation guide
Digital Monitoring Products XT30/XT50 Programming Guide
30
zone informaTion
13.10.7
ACTION: XXXXXXX
Button Action
This option species the Button Action for an individual key fob button. The default
action for the button selected is displayed. Press any Select key to display the
Button Action options. To view more options press the COMMAND key.
ARM DIS TGL STA
ARM (Arm) - Arms selected areas and force arms bad zones.
DIS (Disarm) - Disarms selected areas.
TGL (Toggle Arm) - Toggles arm/disarm for selected areas and force arms bad zones
when arming.
STA (Status) - Causes the key fob LED to indicate the arm/disarm status of the
system.
PN PN2 EM EM2
PN (Panic) - Triggers a Panic zone type alarm with no restoral.
PN2 (Panic 2) - Triggers a Panic zone type alarm with no restoral when pressed
simultaneously with any other Panic 2 button. No action occurs when pressed
alone.
EM (Emerg) - Triggers an Emergency zone type alarm with no restoral.
EM2 (Emerg 2) - Triggers an Emergency zone type alarm with no restoral when
pressed simultaneously with any other Emergency 2 button. No action occurs when
pressed alone.
OUT RST UN
OUT (Output) - Causes an output to turn on steady, pulse, momentary, toggle or off.
RST (Sensor Reset) - Causes the panel to perform a standard Sensor Reset.
UN (Unused) - The button is not used and performs no action.
13.10.8
PRESS TIME: XXXXX
Button Press Time
This option species the amount of time (SHORT or LONG) the user must press the
button before the key fob sends a message to the wireless receiver. The default
press time displays. Press any Select key to set the Button Press Time for Arm,
Disarm, Toggle, Status, Output, and Sensor Reset.
Note: The Button Press Time is not programmable on Panic (PN or PN2), Emergency
(EM or EM2) or Unused (UN) zones. For those zones the button press time is always
two (2) seconds.
SHORT LONG
SHORT - Press the button for one-half (1/2) second to send the message to the
wireless receiver.
LONG - Press the button for two (2) seconds to send the message to the wireless
receiver.
13.10.9
AREA: 1 2 3 4
Arm/Disarm Area Selection
For Area systems, enter the areas, 1 to 4, to be armed/disarmed by the Key Fob
button being programmed.
ARM AREAS: PERIM
This species the area to be armed by the Key Fob button being programmed.
For All/Perimeter systems, choose PERIM or ALL.
For Home/Sleep/Away or Home/Away systems, choose HOME, SLEEP, or AWAY.
After selecting the areas, for one-button key fobs the Zone No.: prompt displays.
For two-button or four-button key fobs, the Key Fob Button Selection option
displays to program additional buttons.
13.10.10
OUTPUT NO: 0
Output Number
You can specify a relay output to operate when OUT (Output), PN (Panic), PN2
(Panic 2), EM (Emergency), or EM2 (Emergency 2) is selected for a key fob Button
Action and the button is pressed. Valid range is 1 to 4. For an output turned on
by a PN, PN2, EM, or EM2 button action, the output turns off when any area is
disarmed.
To enter an output number, press a top row Select key followed by the output
number. Press the COMMAND key.