13.9.2
CONTACT: INTERNAL
Contact
This option displays if the serial number entered is for an 1101 or 1103 Universal
Transmitter or 1114 Wireless Four-Zone Expander. Press any top row key to select
the contact.
INT EXT
This option displays when programming an 1101 or 1103 Transmitter. Select INT to
use the internal reed switch contacts. Select EXT to connect an external device to
the 1101 or 1103 terminal block. Default is INTERNAL.
By allowing both of the Model 1101 or 1103 transmitter contacts (INT and EXT) to be
used at the same time, two zones may be programmed from one transmitter. When
using both contacts, you must use consecutive zone numbers.
For example, program transmitter serial number 01345678 as Zone 11 with an INT
contact type and Zone 12 with an EXT contact type. The same serial number is used
for both zones.
CONTACT: x
This option displays when programming an 1114 zone expander which provides four
input contacts. Press any top row key to select the contact. Default is Contact 1.
1 2 3 4
Select the contact number to program. The same transmitter serial number is used
for all four contacts. When using the contacts, you must use consecutive zone
numbers.
For example, use serial number 08345678 to program Contact 1 for Zone 21,
Contact 2 for Zone 22, Contact 3 for zone 23, and Contact 4 for zone 24.
A tamper on the 1114 is transmitted as the zone number assigned to Contact 1.
ALREADY USED Zxx
This message displays when the Contact is already programmed for another zone.
The programmed zone number displays.
NORM OPEN NO YES
The Normally Open option only displays when EXT is selected as the Contact
type. For external devices connected to the 1101 terminal block, select NO to use
normally closed (N/C) contacts. Select YES to use normally open (N/O) contacts.
Default is NO.
13.9.3
SUPRVSN TIME: XX
Supervision Time
Press any top row key to select the supervision time required for the wireless zone.
Press COMMAND to accept the default time. Default is 240 minutes.
0 3 60 240
Select the required number of minutes. The transmitter must check in at least
once during this time or a missing condition is indicated for that zone. 1100 Series
transmitters automatically checkin based on the supervision time selected for the
wireless zone, no additional programming is needed. If two zones share the same
transmitter, the last programmed supervision time is stored as the supervision time
for both zones. Zero (0) indicates an unsupervised transmitter.
Note: When the panel is reset or a receiver is installed or powered down and
powered up, the supervision timer restarts for all wireless zones.
13.9.4
LED OPER NO YES
LED Operation
This only displays when programming a panic or pendant transmitter. Select YES to
turn a panic or pendant LED on during normal operation. Select NO to turn the LED
off during normal operation. The LED always operates on all transmitters when the
transmitter case is open and the tamper is faulted. Default is YES.
13.9.5
NEXT ZN NO YES
Next Zone
Select YES to return to the ZONE NO: - prompt to program a new zone. Select NO
to display the Alarm Action option.