Installation guide

Digital Monitoring Products XT30/XT50 Programming Guide
26
zone informaTion
If you select Blank, Night, Day, Exit, Auxiliary 1, or Auxiliary 2 as the Zone Type,
the zone must be assigned to an area. If you select Fire, Panic, Emergency, or
Supervisory as the Zone Type, these are 24-hour zones that are always armed and no
area assignment is needed. Press COMMAND to continue.
CAUTION: When a sensor reset is performed at the keypad, power will drop to devices
connected to zone 10 causing the panel to sense an open condition on all zone types
other than Fire (FI), Fire Verify (FV), and Supervisory (SV). Whenever non-Fire and non-
Supervisory zone types are used on zone 10, make the appropriate adjustments to the
zone Armed Action to prevent false alarms from occurring.
Refer to the Appendix for zone type specications and descriptions.
Note: For NRTL listed installations using wireless zones, do not use the FV zone
type.
13.6
AREA NO: -
Area Assignment
For Area systems, enter the area number from 1 to 4 where this zone is being
assigned.
AREA: PERIMETER
For All/Perimeter systems, choose INTERIOR or PERIMETER.
INT BEDRM PERIM
For Home/Away systems, choose INTERIOR, PERIMETER, or BEDROOMS.
• INT (Interior) - Assigns the zone to area 2, Interior.
• BDRM (Bedroom)- Assigns the zone to area 3, Bedrooms. This option is only
displayed in Home/Away systems.
• PERIM (Perimeter) - Assigns the zone to area 1, Perimeter.
13.7
AREA:
Arming Zone Assignment
For Area systems, this option species the areas to be armed by the Arming Type
zone. Press the appropriate number keys on the keypad to assign areas 1 to 4.
When disarmed, all programmed areas are disarmed.
ARM AREA: PERIM
For All/Perimeter systems, choose PERIM or ALL. For Home/Away systems, choose
HOME, SLEEP, or AWAY.
PERIM ALL
Perimeter/All - Specify whether the arming zone arms just the Perimeter (PERIM) or
the Perimeter and Interior areas (ALL) for All/Perimeter systems. When disarming,
all areas are disarmed.
HOME SLEEP AWAY
HOME/SLEEP/AWAY - Specify whether the arming zone arms the Perimeter (HOME),
the Perimeter and Interior (SLEEP), or all three areas (AWAY). When disarming, all
areas are disarmed.
Arming zone operation
If a bad (faulted) Priority zone is in the area being armed by an Arming zone,
the arming is stopped. If there are no Priority zones, or they are all in a normal
condition, the following applies:
When a non-Priority zone is bad when an area is armed with a keyswitch on an
Arming zone, the arming is delayed for ve seconds. If, during the ve-second
delay, the keyswitch is turned to disarm, the arming stops. If the keyswitch is held
in the arming position for the full ve seconds, the bad zone is force armed and the
area is armed.
The ability to stop the arming does not apply if a wireless arming device is being
used. Refer to the Appendix.
Note: Arming from a zone, voice module, touch tone telephone, or Remote Link is
not affected by this operation.
13.7.1
STYLE: TOGGLE
Style
This option species the style for the arming/disarming operation. The default for
STYLE: is TGL (toggle). Pressing any Select key displays the STYLE options. To
view more style options press the command key. The following is a description of
the action for each option condition.
TGL ARM DIS STEP
TGL (Toggle) - When the zone changes from normal to shorted, the programmed