ZONE INFORMATION
Zone Information
This allows you to dene the operation of each protection zone used in the system.
13.2
ZONE NO: -
Zone Number
Enter the number of the zone you intend to program. Press COMMAND to enter a
zone name. Refer to the Enter Alpha Characters section.
Keypad Address Zone Numbers
1 11-14
2 21-24
3 31-34
4 41-44
5 51-54
Note: Use zone numbers 31 to 34 or
41 to 44 with 1100 Series Key Fobs or
DMP wireless output modules.
The XT50 has 20 onboard wireless zones numbered 80-99 or can be programmed to
use zones 11-54 as wireless. Since the XT50 contains a built-in 1100 Series Receiver
any keypad bus zone can be programmed as wireless while the next consecutive
zone number can be hardwire from a keypad or zone expander.
When using the XT30 panel any wireless input zone for a particular device address is
programmed (Ex: 11-14 = Addr 1), the 1100D/1100DH/1100DI responds to the panel
for this address. Other devices, such as keypads or hardwired zone expanders,
cannot use this address. Zones connected directly to the panel cannot be wireless.
13.3
KEYFOB NO YES
Key Fob
Select YES to program an 1100 Series Key Fob for zones 31-34 or 41-44. When YES
is selected, programming continues at the 1100 Series Key Fobs Section. Default is
NO.
13.4
* UNUSED *
Zone Name
Press any Select key and enter up to 16 characters for the zone name. A name must
be given to each zone in the system. This name can be displayed at the keypads
when the zone is bad or viewed in Display Events. The zone name is also sent to the
receiver as part of a zone event report.
A zone that is not part of the system must be marked *UNUSED*. To mark a zone
unused, de lete the old name by pressing any Select key, then press the COMMAND
key. The pro grammer auto matically pro grams the name as * UNUSED *. If you
selected ZONES? NO YES to clear the panel’s memory during Initialization, the
zones will already be marked * UNUSED *. See the Initialization section.
13.5
ZONE TYPE: -
Zone Type
The Zone Type denes the panel’s response to the zone being opened or shorted.
See the Zone Types Specications chart.
When you assign a Zone Type to a zone, responses are made automatically for the
zone. There are 11 Zone Types to choose from including Blank. The func tional
details of each response are described in Zone Types Specication.
To select a new Zone Type, press any Select key. The display lists the four Zone
Types shown below. When the Zone Type you want to select displays, press the
Select key below the name.
FI PN EM SV
A1 A2 FV AR
-- NT DY EX
Blank, Night, Day, or Exit. Press COMMAND to display additional zone types.
Fire, Panic, Emergency, or Supervisory. Press COMMAND to display additional zone types.
Auxiliary 1, Auxiliary 2, Fire Verify, or Arming. Press the Back Arrow key to display
the previous zone types.