Installation guide

XT30/XT50 Programming Guide Digital Monitoring Products
23
ouTPuT informaTion
Output Information
11.1
OUTPUT INFO
Output Information
This section allows you to program and name wireless outputs into the panel when
using an 1100D/1100DH/1100DI Wireless Receiver with an XT30 panel or the built-in
receiver of the XT50. Wireless outputs are also available on the XT50 when using
an onboard receiver. Output Information only displays when a House Code (1-50) is
entered in System Options programming.
11.2
OUTPUT NO: -
Output Number
Enter an output number. Entry range is 31 to 34, 41 to 44.
Note: Addresses 31 to 34 and 41 to 44 are available for wireless outputs, keypad
bus zones, wireless zones or wireless key fob zones and can only be assigned to one
device.
11.3
* UNUSED *
Output Name
This section allows you to dene a 16 character alphanumeric name for any wireless
output.
An output that is not part of the system must be marked *UNUSED*. To mark an
output unused, de lete the old name by pressing any Select key, then press the
COMMAND key. The pro grammer auto matically pro grams the name as * UNUSED *.
11.4
SERIAL#: -
Serial Number
Enter the eight-digit serial number found on the wireless device.
ALREADY USED: ZXX
This message displays when the serial number is already programmed for another
output or zone. The programmed output or zone number displays.
11.5
SUPRVSN TIME: 240
Supervision Time
Press any top row key to select the supervision time required for the wireless
output. Press COMMAND to accept the default time. Default is 240 minutes.
0 3 60 240
Select the required number of minutes. The transmitter must check in at least
once during this time or a missing condition is indicated for that zone. 1100 Series
transmitters automatically check in based on the supervision time selected for
the wireless zone, no additional programming is needed. Zero (0) indicates an
unsupervised transmitter.
Note: When the panel is reset, a receiver is installed or powered down and
powered up, or programming is complete, the supervision timer restarts for all
wireless outputs.