Installation guide
Digital Monitoring Products XT30/XT50 Programming Guide
22
ouTPuT oPTionS
10.6
ENTRY OUT: 0
Entry Output
This output turns on at the start of the entry delay time. The output turns off when
the area disarms or the entry delay time expires. Enter 0 (zero) to disable.
10.7
EXIT OUT: 0
Exit Output
This output turns on any time an exit delay time starts. The output turns off when
the system arms or when the arming has been stopped. Enter 0 (zero) to disable.
10.8
READY OUT: 0
Ready Output
This output turns on whenever all disarmed zones are in a normal state. The output
turns off when any disarmed zone is in a bad state. Enter 0 (zero) to disable.
10.9
ARMED OUT: 0
Armed Output
This output turns on any time an area of the system arms. The output turns off
when the system completely disarms. Enter 0 (zero) to disable this output.
10.10
BURGLARY OUT: 0
Burglary Output
This output turns on any time a burglary zone goes into alarm. The output turns off
when the area in which the alarm occurred disarms and no other burglary zones are
in alarm. Enter 0 (zero) to disable this output.
10.11
LATE CLS OUT: 0
Late To Close Output
Enter the output number to turn on at the expiration of a closing schedule when all
areas are not armed. The output activates simultaneously with the CLOSING TIME!
keypad display. The output is turned off when all areas are armed, the closing is
extended, or the schedule is changed.
10.12
ARM-ALARM OUT: 0
Arm-Alarm Output
Enter the output number to turn on steady when any area of the system is armed.
If an alarm occurs causing the keypads to turn Red, this output pulses and continues
to pulse for approximately ve (5) minutes after the panel is disarmed. Enter 0
(zero) to disable.
Wireless Outputs
• The Arm-Alarm Output is compatible with the Model 1117 Wireless LED
Annunciator and the Model 1116 Wireless Relay Output connected to a Model
572 Indicator LED.
• When the Model 1117 is battery operated, the LED is off when the system
is armed to conserve battery life. If an alarm occurs, the output ashes
quickly.
• When using the Model 1116 connected to a Model 572, the LED is on when
the system is armed. If an alarm occurs, the output pulses.
• To operate the Arm-Alarm output within one second, program a fast response
number from 41 to 44. Fast response operation reduces overall wireless
output battery life.
• To operate the Arm-Alarm output within 15 seconds, program a slow
response number from 31 to 34. Slow response operation increases overall
wireless output battery life.