This section allows you to program panel output options. Switched Ground (open
collector) outputs are available using the 4-wire output harness on the XT30/XT50
board. Wireless outputs are available when using the built-in 1100 Series Receiver
of the XT50 or an 1100D Wireless Receiver with the XT30. Refer to the XT30/XT50
Installation Guide (LT-0624) for complete information.
Select from the following output numbers:
• 1 to 4
• 31 to 34 —
Slow response
time
*
wireless outputs (activate within 15 seconds)
• 41 to 44 — Fast response time* wireless outputs (activate within 1 second)
* The response time of a wireless output is the time it takes for a wireless output to
activate once the panel event occurs. You determine whether a wireless output is a
slow or fast response based on the output number assigned. A slow response output
number extends battery life, but response time may be up to 15 seconds. A fast
response output number responds within 1 second, but reduces battery life. Refer to
the specic wireless output installation guide to determine battery life.
10.2.1
CO OUTS: - - - -
Cutoff Outputs
This option allows you to dene the operation of the four on-board annunciator
outputs. For each programming option, enter the number of the output you wish
to activate or 0 (zero) for no output. Any or all of the available outputs can be
programmed here to turn off after the time specied in Output Cutoff Time.
See the Output Cutoff Time section for additional information. To disable this
option, press any Select key to clear the display of output numbers and then press
COMMAND.
Note: Whenever an output is assigned in Output Options, that output cannot be
turned on from the User Menu.
10.2.2
CUTOFF TIME: 0
Output Cutoff Time
If a Cutoff Output is assigned, you can enter a Cutoff Time for the output to remain
on up to 15 minutes. If the output is turned off manually, the cut off time is reset.
The Cutoff Time can be 1 - 15 minutes. Enter 0 (zero) to provide continuous output.
The Cutoff Timer is shared by all outputs. If a second output trips, the timer is not
reset. Both outputs turn off when the original time expires.
10.3
COM FAIL OUT: 0
Communication Failure Output
This output turns on when the panel fails to communicate with the receiver after
three successive dial attempts. Enter 0 (zero) to disable this output.
Note: To turn off the Communication Failure Output, disarm the panel or turn the
output off using the User Menu Outputs On/Off function.
10.4
FIRE ALR OUT: 0
Fire Alarm Output
This output turns on any time a re type zone is placed in alarm. The output turns
off using the Sensor Reset option when no additional re type zones are in alarm.
Enter 0 (zero) to disable this output.
10.5
FIRE TRB OUT: 0
Fire Trouble Output
This output turns on any time a re type zone is placed in trouble or when a
supervisory type zone is placed in alarm or trouble. The output turns off when all
re and supervisory type zones restore to normal. Enter 0 (zero) to disable.
10.6
AMBUSH OUT: 0
Ambush Output
This output turns on any time an Ambush code is entered at a keypad. The output