This section allows you to enter the information needed to receive messages
directly from the panel via email and cellular communication. All of the name and
address options below allow up to 32 lowercase characters to be entered. System
Name will display with initial caps.
The transmitted messages are:
• Zone Alarms by Zone Name
• Zone Troubles by Zone Name
• Zone Bypass by User
• Arming (Closings) by User
• Disarming (Openings) by User
• Late to Close
• AC Power Trouble and Restoral
• System Low Battery
• Ambush
• Abort, Cancel and Alarm Veried by User
• Check-in by user
Note: If messages will be sent via cellular communication, the SIM card of the
XT30/XT50 panel or 263G Digital Cellular Communicator must be upgraded to the
Level 400 SIM card. Order model number 380-400 to obtain the Level 400 SIM Card.
5.2 Enable Messaging
Select YES to allow the panel to send messages to three programmed destinations.
Default is NO.
5.3
SYSTEM NAME
System Name
Enter a unique name for the panel. The panel name will be used as the sender of the
message. The text entered will be displayed with initial caps. If this eld is left blank,
the panel account number will be sent.
5.4
DESTINATION 1
Destination 1
-
Enter the rst email address or cell phone number that messages will be sent
to. The message can be sent to any device (computer, cell phone, PDA) as long
as a valid email address or cell phone number is entered. When entering email
addresses, press the 7 digit key followed by the fourth Select Key to add the @
symbol and the 9 digit key followed by the fourth Select Key to add the _ symbol.
See the Entering Non-Alpha Characters section for addditional symbols.
Note: Mail servers that require Transport Layer Security (TLS) encryption are not
supported by the XT30/XT50.
5.5
DESTINATION 2
Destination 2
-
Enter the second email address or cell phone number that messages will be sent to.
5.6
DESTINATION 3
Destination 3
-
Enter the third email address or cell phone number that messages will be sent to.
5.7
EMAIL COMM TYPE
Email Communication Type
NET CELL
Choosing NET will ensure that email messages are sent over the network. Choosing
CELL will ensure that email messages are sent via cellular communication. Default
is NET. This prompt appears only if any destination above is an e-mail and the panel
is a network panel (has an Ethernet connector).
Note: If messages will be sent via cellular communication, the SIM card of the
XT30/XT50 panel or 263G Digital Cellular Communicator must be upgraded to the
Level 400 SIM card. Order model number 380-400 to obtain the Level 400 SIM Card.
ENABLE MESSAGING