Installation guide
XT30/XT50 Programming Guide Digital Monitoring Products
7
CommuniCaTion
Communication
3.1
COMMUNICATION
Communication
The Communication section allows you to congure the communication settings for
the XT30/XT50 panel. After choosing the Communication Type, continue through
the list of options.
3.2
ACCOUNT NO:
Account Number
Enter the account num ber sent to the receiver.
DD, NET, CELL - The range of account numbers for Digital Dialer, Network, and
Cell is 1 to 65535. For account numbers of four digits or less, you do not have to
enter leading zeros. The panel automatically right justies the account number.
CID - The account number range for this format is 1 - 9999.
3.3
XMIT DELAY: 30
Transmission Delay
Enter the number of seconds (15 to 45 seconds) the panel waits before sending
burglary alarm reports to the receiver. The bell and relay outputs are not delayed
during this period. Program Burglary Outputs for steady, and set Abort Reports to
YES if Opening and Closing reports are not being sent. Enter 0 (zero) to disable this
function. The default is 30.
If the area where the alarm occurred is disarmed during the Transmit Delay time,
only an Abort Report (S45) message is sent to the receiver. If the area where the
alarm occurred is disarmed after the alarm message is sent to the receiver but
before the Bell Cutoff time expires, even if the alarm was silenced, an Alarm
Cancelled (S49) message is sent. The Alarm Cancelled report cannot be disabled.
3.4
COMM TYPE: DD
Communication Type
This species the communication method the panel uses to contact the receiver.
Press any Select key to display the following communication options:
DD CID NET CELL
NONE
DD - Digital Dialer communication to DMP SCS-1R Receivers.
CID - Contact ID dialer communication to non-DMP receivers. This format sends the
report codes of the Ademco Contact ID communication format.
NET - Network communication to DMP Model SCS-1R Receivers.
CELL - Cellular communication to DMP Model SCS-1R Receivers.
NONE - For local systems. Selecting this ends communication programming.
NOTE: The Backup Dialer, Backup Cellular, Check-in Minutes, and Failed Minutes
options revert to their default values when the communication type is changed. All
other communication programming items remain at their programmed values.
3.5
BACKUP DIALER
Backup Dialer
NO YES
Backup Dialer option is available if COMM TYPE is set for NET or CELL. The Backup
Dialer tries to send the message after the main communication fails for 60 seconds
on NET and 4 send attempts with CELL. If the backup dialer fails then the message
is discarded.
3.6
BACKUP CELL
Backup Cellular
NO YES
Backup Cellular option is available if COMM TYPE is set for NET or DD/CID. The
Backup Cellular tries to send the message after the main communication fails for 60
seconds on NET and 10 dial attempts with DD/CID. If the backup dialer fails then
the message is discarded.