UL 1635 Specications
Digital Burglar Alarm Communicator System Units
19.1 Digital Dialer Telephone Number
Both programmed telephone numbers must begin with a D or P. See the Programming Guide (LT-0305).
19.2 Entry Delay
The maximum entry delay used must not be more than 60 seconds. See the Programming Guide (LT-0305).
19.3 Exit Delay
The maximum exit delay used must not be more than 60 seconds. See the Programming Guide (LT-0305).
19.4 Test Frequency
The Test Frequency option must be programmed to send a report once every 24 hours. See LT-0305.
19.5 Automatic Bell Test
This option must be programmed as YES. See the XRSuper6/XR20/XR40 Programming Guide (LT-0305).
19.6 Grade B Central Station
Grade B Central Station service can be provided under UL 1635 by adding a Grade A local audible signal
appliance and placing the XRSuper6/XR20/XR40 panel and all standby batteries into the Model 350A Grade A
Attack Resistant Housing.
Universal UL And NFPA Fire Alarm Specications
20.1 Introduction
The programming and installation specications contained in this section must be completed when installing
the Model XRSuper6/XR20/XR40 in accordance with any of the UL or NFPA re standards. Additional
specications may be required by a particular standard.
20.2 Wiring
All wiring must be in accordance with NEC, ANSI/NFPA 70.
20.3 Police station phone number
The digital dialer telephone number programmed for communication must not be a police station phone
number, unless that phone number is specically provided for that purpose.
20.4 System maintenance
Proper installation and regular maintenance by the installing alarm company and frequent testing by the end
user is essential to ensure continuous satisfactory operation of any alarm system. Offering a maintenance
program and acquainting the user with the correct procedure for use and testing of the system is also the
responsibility of the installing alarm company.
20.5 Audible alarm
Fire Type zones should be programmed to activate an audible alarm. The Bell Action for Fire Type zones
should not be programmed as “N.” See the XRSuper6/XR20/XR40 Programming Guide (LT-0305).
20.6 Fire zone programming
Fire zones must be programmed to activate a trouble on open conditions and an alarm on short conditions.
The swinger bypass function must not be used on any re zones. See the Programming Guide (LT-0305).
20.7 Ground Start
Ground Start phone lines must not be used for UL listed systems.
20.8 UL Listed Receivers
UL has veried operation with the DMP SCS-1/SCS-1R Security Receiver, Sur-Gard MLR2-E, SG-HLR2-DG, FBII
CP220PB, Osborne-Hoffman Quick-Alert, and Radionics D6500 receivers.