COMPLIANCE
XRSuper6/XR20/XR40 Installation Guide Digital Monitoring Products
15
COMPLIANCE
16.5 Wireless External Contact
When used, the External Contact of 1101, 1102, or 1103 must be programmed Normally Closed. See the
XRSuper6, XR20, XR40 Programming Guide (LT-0305).
16.6 Wireless Supervision Time
The Zone Information Supervision Time must be a maximum of 60 minutes. See the XRSuper6, XR20, XR40
Programming Guide (LT-0305).
UL 1610 and 1076 Specications
Central-Station and Proprietary Burglar-Alarm Units
17.1 Opening/Closing Reports
The Opening/Closing Reports option must be programmed as YES. See the Programming Guide (LT-0305).
17.2 Automatic Bell Test
This option must be programmed as YES. See the XRSuper6/XR20/XR40 Programming Guide (LT-0305).
17.3 Proprietary Dialer
The Model XRSuper6/XR20/XR40 provides Grade A proprietary service when congured as a digital dialer.
17.4 AA High Line Network Security
UL AA High Line Security is provided when congured as a NET system using an XRSuper6, XR20, or XR40
panel with an iCOMSL™ Network Alarm Router. The NET Check-in time must be set from 01 to 06 minutes.
When a dialer is required for 06 minute check-in time, an attack resistant enclosure (DMP Model 350A)
is required. When the check-in time is set to a number less than 200 seconds (1, 2, or 3 minutes), an
attack resistant enclosure is not required. See the Communication section of the XRSuper6, XR20, XR40
Programming Guide (LT-0305).
17.5 Wireless Arming Mode
The System Options Mode for arming must be programmed as Area or All/Perimeter (A/P). See the
XRSuper6/XR20/XR40 Programming Guide (LT-0305).
17.6 Wireless Tamper
The Zone Information Disarmed Open Message to Transmit must be programmed Trouble (T). See the
XRSuper6/XR20/XR40 Programming Guide (LT-0305).
17.7 Wireless External Contact
When used, the External Contact of 1101, 1102, or 1103 must be programmed Normally Closed. See the
XRSuper6/XR20/XR40 Programming Guide (LT-0305).
17.8 Wireless Supervision Time
Set the Zone Information Supervision Time to 60 minutes maximum. See the XRSuper6/XR20/XR40
Programming Guide (LT-0305).