INSTALLATION GUIDE XRSUPER6 / XR20 / XR40 COMMAND PROCESSOR™ PANELS
MODEL XRSuper6/XR20/XR40 COMMAND PROCESSOR INSTALLATION GUIDE FCC NOTICE This equipment generates and uses radio frequency energy and, if not installed and used properly in strict accordance with the manufacturer’s instructions, may cause interference with radio and television reception.
TABLE OF CONTENTS Revisions to This Document Panel Specifications 1.1 1.2 1.3 1.4 1.5 1.6 Power Supply .........................................1 Communication.......................................1 Panel Zones............................................1 Keypads .................................................1 Outputs..................................................1 Enclosure Specifications ..........................1 Introduction 2.1 2.2 2.3 2.4 2.5 Description ....................................
TABLE OF CONTENTS Burglary Zones 10.1 10.2 10.3 10.4 Description ...........................................10 Operational Parameters .........................10 Zone Response Time .............................10 Keyswitch Arming Zone .........................10 Powered Zone for 2-Wire Smoke Detectors 11.1 Terminals 25 and 26..............................11 11.2 Wiring Zone 10 on XR20/XR40 ...................12 Annunciator Outputs 12.1 12.2 12.3 Description ...........................................
TABLE OF CONTENTS UL 365 And 609 Specifications 18.1 18.2 18.3 18.4 18.5 18.6 18.7 18.8 18.9 18.10 18.11 18.12 Entry Delay ..........................................16 Grade A Bell .........................................16 Bell Cutoff ............................................16 Automatic Bell Test ...............................16 Grade A Mercantile................................16 Mercantile Safe and Vault ......................16 Line Security for Police Connect .............
REVISIONS Revisions to This Document This section explains the changes that were made to this document during this revision. This section lists the date the change was made, the section number and heading, and a quick summary of the change. Date 8/06 Section Number and Heading 3.5 Wiring Diagram 6.1 Battery Terminals 3 & 4 Listings and Approvals Summary of Changes Added SIA CP-01 information. Added figure and text to clarify use of battery harnesses and PTC. Note: Subsequent figure numbers changed.
INTRODUCTION Panel Specifications 1.1 Power Supply Transformer Input: Wire-in — 16.5 VAC 40 VA, Model 320 Plug-in — 16.5 VAC 40 VA, Model 321 Standby Battery: 12 VDC 7.0 Ah (40 VA transformer charges up to 2 batteries) Auxiliary Output: 12 VDC at 500mA Bell Output: 12 VDC at 1.5 Amps Smoke Detector Output: 12 VDC at 100mA All circuits inherent power limited 1.
INTRODUCTION Introduction 2.1 Description The DMP XRSuper6/XR20/XR40 Command Processor™ panels are powerful 12 VDC burglary and fire communicator panels with battery backup. The XR20 and XR40 panels provide nine on-board burglary zones and one on-board 12 VDC Class B powered fire zone. The XRSuper6 provides five burglary zones and one fire zone. The fire zone has a reset capability to provide for 2-wire smoke detectors, relays, or other latching devices.
INTRODUCTION System Components 3.1 Description The DMP system is made up of an alarm panel with built in communicator, an enclosure, a 16.5 VAC transformer, and a 12 VDC 7.0 Ah battery. You can add Security Command keypads to the system and can also connect auxiliary devices to the panel’s open collector outputs to expand the basic system. Combined current requirements of additional modules may require an auxiliary power supply.
INTRODUCTION 3.5 XRSuper6/XR20/XR40 Wiring Diagram RJ Cable Monitor J7 Use DMP Model 306 Harness J7 RJ SUP Phone Jack Connector J8 RED PROG 4 6 8 7 10 9 Bell 22 gauge minimum Cold Water Pipe Earth Ground 22 gauge minimum s 22 gauge minimum s Maximum AC Wire distance with 16 gauge wire: 70 feet with 18 gauge wire: 40 feet RED BLACK Up to 500mA auxiliary current at 10.4 to 13.2 VDC from Terminals 7, 11, 25, and 26.
INSTALLATION Installation 4.1 Mounting the Enclosure The metal enclosure must be mounted in a secure, dry place to protect the panel from damage due to tampering or the elements. It is not necessary to remove the PCB when installing the enclosure. The PCB may be installed in the standard 340 enclosure or the optional 349 enclosure. The panels can also be installed in the 341 or 342 small enclosure. The XRSuper6, XR20, or XR40 panels may optionally be installed in the 350A Grade A enclosure.
INSTALLATION 4.2 Mounting Keypads DMP keypads have removable covers that allow you to easily mount the base to a wall or other flat surface using the screw holes provided on each corner. For mounting keypads on solid walls, or for applications where conduit is required, use a DMP 695, 696, 775, or 776 keypad conduit backbox. 4.
INSTALLATION Secondary Power Supply 6.1 Battery Terminals 3 and 4 Connect the black battery lead to terminal 4 on the panel and to the negative terminal of the battery. The negative terminal connects to the enclosure ground internally through the panel circuit board. Connect the red battery lead to terminal 3 on the panel and to the positive terminal of the battery. Observe polarity when connecting the battery. The panel can charge up to two batteries.
INSTALLATION 6.
INSTALLATION Bell Output 7.1 Terminals 5 and 6 Nominal 12 VDC is supplied by terminal 5 on the panel to power alarm bells or horns. The output is rated for a maximum of 1.5 Amps with a 40 VA transformer. This output can be steady, pulsed, or Temporal Code 3 depending upon the Bell Action specified in Output Options programming. Terminal 6 is the ground reference for the bell circuit. Keypad Data Bus 8.1 Description Terminals 7, 8, 9, and 10 of the panel are designated as the keypad data bus.
INSTALLATION Burglary Zones 10.1 Description On XR20/XR40 panels, terminals 12 to 24 are the nine burglary zones. For programming purposes, the zone numbers are 1 to 9. The zone configurations on terminals 12 to 24 are described below. The XRSuper6 terminals 12 to 18 are the five burglary zones with terminal 16 providing the ground for zone 5 (terminal 18).
INSTALLATION Powered Zone for 2-Wire Smoke Detectors 11.1 Terminals 25 and 26 A resettable 2-wire Class B powered zone is provided on terminals 25 (positive) and 26 (negative) of the panel. For programming purposes, the zone number is 10 on the XR20/XR40 and zone 6 on the XRSuper6. The zone uses a Model 309, 3.3k Ohm EOL resistor (provided with the panel) and has an operating range of 8.8 to 14.2 VDC. The UL compatibility identifier is: A.
INSTALLATION 11.2 Wiring Zone 10 on XR20/XR40 The end-of-line resistor for zone 9 must not be accidentally connected to the positive terminal of zone 10 as shown below. When zone 9 is incorrectly connected to zone 10, a false alarm may occur on zone 2 of the panel when the panel picks up the telephone line to communicate to the receiver.
INSTALLATION Telephone RJ Connector 13.1 Description Connect the panel to the public telephone network by installing a DMP 356 RJ Cable between the panel’s J4 connector and the RJ31X or RJ38X phone jack. A two pin header labeled RJ SUP (J7) is provided to allow monitoring of the telephone cable connected between the panel and a RJ38X jack (pins 2 and 7 jumpered). Attach a DMP Model 306 Harness between J7 and any available zone.
COMPLIANCE Universal UL Burglary Specifications 15.1 Introduction The programming and installation specifications contained in this section must be completed when installing the XRSuper6/XR20/XR40 in accordance with any of the UL burglary standards. Additional specifications may be required by a particular standard. 15.2 Wiring All wiring must be in accordance with NEC, ANSI/NFPA 70, UL 681, and UL 611 for all burglary installations. 15.
COMPLIANCE 16.5 Wireless External Contact When used, the External Contact of 1101, 1102, or 1103 must be programmed Normally Closed. See the XRSuper6, XR20, XR40 Programming Guide (LT-0305). 16.6 Wireless Supervision Time The Zone Information Supervision Time must be a maximum of 60 minutes. See the XRSuper6, XR20, XR40 Programming Guide (LT-0305). UL 1610 and 1076 Specifications Central-Station and Proprietary Burglar-Alarm Units 17.
COMPLIANCE UL 365 And 609 Specifications Police Station Connected and Local Burglar Alarm Units and Systems 18.1 Entry Delay The maximum entry delay must not exceed 60 seconds with the Model 350A Grade A housing. See LT-0305. 18.2 Grade A Bell A Grade A local audible signal appliance must be used. 18.3 Bell Cutoff The bell cutoff time cannot be less than 15 minutes. See the Programming Guide (LT-0305). 18.4 Automatic Bell Test The Automatic Bell Test option must be programmed as YES.
COMPLIANCE UL 1635 Specifications Digital Burglar Alarm Communicator System Units 19.1 Digital Dialer Telephone Number Both programmed telephone numbers must begin with a D or P. See the Programming Guide (LT-0305). 19.2 Entry Delay The maximum entry delay used must not be more than 60 seconds. See the Programming Guide (LT-0305). 19.3 Exit Delay The maximum exit delay used must not be more than 60 seconds. See the Programming Guide (LT-0305). 19.
TROUBLESHOOTING UL 985 NFPA 72 (Chapter 2) Specifications Household Fire Warning System Units 21.1 Bell output definition The bell output of the Model XRSuper6/XR20/XR40 must be programmed to operate steady on burglary alarms and pulsed on fire alarms. See the XRSuper6/XR20/XR40 Programming Guide (LT-0305). 21.2 Indicating Circuit Supervision The DMP Models 865 and 866 Notification Circuit Module must be used on the bell circuit for detection of shorts and grounds. 21.
TROUBLESHOOTING Troubleshooting 23.1 Troubleshooting Section This section of the Installation Guide provides troubleshooting information for use when installing or servicing an XRSuper6/XR20/XR40 system. Problem Possible Cause Keypad displays “SERVICE REQUIRED” Keypad display is not functional. When a key is pressed, only a short beep is emitted. Keypad beeps when keys are pressed, but will not allow the user to arm or disarm, or enter the User Menu. Possible Solutions J16 Jumper is installed.
Digital Monitoring Products 20 DMP Model 866 37mA at 12 VDC 1k Ω Bell T rouble Bell T rouble Bell B Ð Output Bell B + Output Bell A Ð Output 10 11 9 8 7 6 5 Bell A + Output - 4 Bell Power Ð Input 2 3 1 Bell Power + Input Alarm Input Ground Auxiliary Power Power Supply Trouble Contacts N/C AUXILIARY POWER SUPPLY 8 7 6 5 4 3 2 1 S S S S S S S DMP Model 865 85mA at 12 VDC S S S S S S 12 or 24 VDC 5 Amp Maximum Notification Circuit Module 12 or 24 VDC 5 Amp Maxim
WIRING DIAGRAMS 24.
OPERATING INSTRUCTIONS MODEL XRSuper6/XR20/XR40 PANELS When using Model 692 LED Keypad, please refer to 692 User Guide (LT-0275) NORMAL STANDBY CONDITION When the system is in the normal standby condition, the keypad shows either the time of day/System Ready or a blank display. ALARM CONDITION When the system is in an alarm condition, the keypad keys glow red and the display shows the violated zone name(s) followed by an alarm display. ARMING THE SYSTEM Press the COMMAND key until arming options appear.