Installation guide
XRSuper6/XR20/XR40 Installation Guide Digital Monitoring Products
15
COMPLIANCE
UL 1610 and 1076 SpeciÞ cations
Central-Station and Proprietary Burglar-Alarm Units
17.1 Opening/Closing Reports
The Opening/Closing Reports option must be programmed as YES. See the Programming Guide (LT-0305).
17.2 Automatic Bell Test
This option must be programmed as YES. See the XRSuper6/XR20/XR40 Programming Guide (LT-0305).
17.3 Proprietary Dialer
The Model XRSuper6/XR20/XR40 provides Grade A proprietary service when conÞ gured as a digital dialer.
UL 1635 SpeciÞ cations
Digital Burglar Alarm Communicator System Units
18.1 Digital Dialer Telephone Number
Both programmed telephone numbers must begin with a D or P. See the Programming Guide (LT-0305).
18.2 Entry Delay
The maximum entry delay used must not be more than 60 seconds. See the Programming Guide (LT-0305).
18.3 Exit Delay
The maximum exit delay used must not be more than 60 seconds. See the Programming Guide (LT-0305).
18.4 Test Frequency
The Test Frequency option must be programmed to send a report once every 24 hours. See LT-0305.
18.5 Automatic Bell Test
This option must be programmed as YES. See the XRSuper6/XR20/XR40 Programming Guide (LT-0305).
18.6 Grade B Central Station
Grade B Central Station service can be provided under UL 1635 by adding a Grade A local audible signal
appliance and placing the XRSuper6/XR20/XR40 panel into the Model 350A Grade A Attack Resistant Housing.
UL 365 And 609 SpeciÞ cations
Police Station Connected and Local Burglar Alarm Units and Systems
19.1 Entry Delay
The maximum entry delay must not exceed 60 seconds with the Model 350A Grade A housing. See LT-0305.
19.2 Grade A Bell
A Grade A local audible signal appliance must be used.
19.3 Bell Cutoff
The bell cutoff time cannot be less than 15 minutes. See the Programming Guide (LT-0305).
19.4 Automatic Bell Test
The Automatic Bell Test option must be programmed as YES. See the Programming Guide (LT-0305).
19.5 Grade A Mercantile
For Grade A Mercantile and Police Station Connect operation the XRSuper6/XR20/XR40 must be mounted in a
Grade A attack resistant housing (DMP Model 350A).
19.6 Mercantile Safe and Vault
When the DMP Model 350A housing is used, the panel provides operation as a mercantile safe and vault
alarm. Bell Supervision and wiring must be in accordance with UL 681. If the panel is mounted outside the
safe or vault, tamper protection and the Sentrol Model 5402 or Potter EVD listed vibration detectors should
be used. The XRSuper6/XR20/XR40 does not provide operation as a Bank Safe and vault alarm.