Programming instructions

2
XR200 Programming Guide
2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282
1 - INTRODUCTION
1.3 Programmer Operation continued
To select a section for programming, press any one of the top row SELECT keys when the name of that section is
displayed on the keypad. The detailed instructions for each programming step are found in sections 2 to 15.
1.4 Programmer Lockout Codes
The XR200 panel allows you to enter the programming function without entering a code using the steps 1 to 4 listed
in section 1.2. We recommend, however, that you install a Lockout Code that restricts programming to only those
persons your company authorizes. You can do this by using the SET LOCKOUT CODE feature in the Programmer.
Use this new Lockout Code to restrict any unauthorized programming of the panel.
Installing a Lockout Code
After resetting the panel and entering the code 6653, the keypad displays PROGRAMMER. Press COMMAND to
advance through the programming sections until SET LOCKOUT CODE is displayed (after STOP). Press any top row
SELECT key. The keypad displays ENTER CODE: – . Enter a 3 to 5 digit Programmer Lockout Code and press
COMMAND. The keypad displays ENTER AGAIN followed by ENTER CODE: –. Enter the same 3 to 5 digit code a
second time and press COMMAND. The keypad displays CODE CHANGED.
Note: The XR200 panel will not accept a 5-digit Lockout Code higher than 65535.
The new code number must now be entered before the programmer function can be accessed.
The Lockout Code should be written down and kept in a secure place with access limited to only those persons
authorized by your company to program the panel.
Lost Lockout Code requires factory reset:
If you lose or forget the Lockout Code, the panel must be sent back to
the factory to be reset. There is no field option for gaining access to the panel without a valid access code.
1.5 Reset Timeout
The XR200 has a feature that requires you to enter the Programmer within 30 minutes of resetting the panel. After 30
minutes, if you attempt to program by entering the 6653 (PROG) code, the keypad displays: RESET PANEL. You
must reset the panel and enter the program code within the next 30 minutes.
If you are already in the Programmer and do not press any keys on the programming keypad for 30 minutes, the
panel terminates programming. All data entered up to that time is saved in the panel's memory.
1.6 Special Keys
COMMAND Key
The COMMAND key allows you to go forward through the
programming menu and through each step of a programming
section. As you go through the programming, the keypad
display shows any current programming already stored in the
panel's memory. If the information is not to be changed,
press the COMMAND key to advance to the next step.
The COMMAND key is also used to enter information into the
panel's memory such as phone numbers or zone names. Press
the COMMAND key after you've entered the information and it's
being displayed correctly on the keypad.
ARROW Key
Use the ARROW key to back up one step while programming.
The ARROW key is also used when an error is made while entering information. Press the ARROW key once to
erase the last character entered.
SELECT Keys
The top row of keys are called the SELECT keys. Each time a SELECT key is to be used, the keypad displays the
function or options above the key. Displaying choices above the individual SELECT keys allows them to be used for
many different applications. For example, you can enter AM or PM when programming the automatic test time or
answer YES or NO for a system option.
12
3
4
567
8
90
COMMAND
A B C
DEF
GHI JKL
VWX
STUPQRMNO
YZ
POWER
ARROW Key
SELECT Keys
Figure 2: Keypad Function keys
COMMAND Key