Programming instructions

34
XR200 Programming Guide
2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282
– = This function is not enabled for this zone type.
+ = Retard must be YES before Presignal can be selected.
= These zone functions are not available for this zone type.
Description of the programmable zone options
Below is a description of the various zone options shown on the table above. For additional information, read through
the Zone Information section of this manual.
Zone Type Defaults - These are complete spellings of the abbreviations used for the zone types.
Type - These are the abbreviations used for the zone types.
RF - This zone is connected to a wireless transmitter.
Message - A = alarm report, T = trouble report, L = local with no report, - (dash) = no report.
Output - These are the ten on-board and 200 off-board relay outputs.
Action - This selects the action of the output: S = steady, P = pulse, M = momentary, and F = follow
Swinger - The zone can be automatically shunted after a programmed number of trips.
Prewarn - This selects the keypad address that sounds the entry prewarn for this zone.
Entry Delay - This is the entry delay timer selected as the default for this zone.
Retard Delay - Provides a programmed retard time before an alarm is initiated from a shorted zone.
Presignal - Provides a keypad tone for zones in retard delay.
Fast Response - Provides a 167ms zone response instead of the normal 500ms response.
Cross Zone - Provides cross zoning with any of the 242 available zones.
Priority - Requires this zone to be in a normal condition before the area can be armed.
Digital Monitoring Products
2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282
16 - APPENDIX
16.7 Zone Type Specifications
ZONE INFORMATION Type Area Fire RF Disarmed Disarmed Armed Armed
– – NT Open Short Open Short
Assign area and disarm condition Bell
for NT, DY, EX, A1, A2, and AR
only
DY EX
Otput
Assign Prewarn and Entry Delay FI PN
for EX only
EM SV 1 Y A 1 S A 1 S A 1 S A 1 S N 1 1 N 1 N N N
Assign Retard and Pesignal
for FI, SV, A1, A2, and FV only A1 A2
1
to or T to P T to P T to P T to P or to to or
to
or or or
FV AR to 1 - 8 10 N L 10 M L 10 M L 10 M L 10 M Y 8 4 Y 8 Y Y Y
Zone type defaults Abbr.
4
100
to
299
D1
to
D16
D
100
to
299
D1
to
D16
F
D
100
to
299
D1
to
D16
F
D
100
to
299
D1
to
D16
F
D
100
to
299
D1
to
D16
F
NIGHT NT 0 0 A 0 A 0 Y N N N
DAY DY T 0 T 0 A 0 A 0 Y N N N
EXIT EX 0 0 A 0 A 0 Y 1-8 1 N N N
FIRE FI T 0 A 0 N N + N N N
PANIC PN T 0 A 0 N N N N
EMERGENCY EM T 0 A 0 N N N N
SUPERVISORY SV T 0 A 0 N N + N N N
AUXILIARY 1 A1 T 0 A 0 T 0 A 0 N N + N N N
AUXILIARY 2 A2 T 0 A 0 T 0 A 0 N N + N N N
FIRE VERIFY FV T 0 A 0 N N N
ARMING AR
Message
Output
Action
Message
Output
Action
Message
Output
Action
Message
Output
Action
Swinger
Prewarn
Entry Delay
Retard Delay
Presignal
Fast Response
Cross Zone
Priority
Partition Number