Programming instructions
30
XR200 Programming Guide
2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282
14.1 STOP
At the STOP prompt, pressing any SELECT key allows you to exit the Programmer function
of the XR200 panel. When selected, the panel performs an internal reset and exits the
programmer.
The STOP routine causes the following conditions to occur:
• All areas in all partitions are DISARMED
• All zones in all partitions are DISARMED
• The panel's Status List is CLEARED
During the reset, all keypad displays are momentarily blank for two seconds. After the reset,
the programming function is terminated and the keypads return to the status list display.
Missing LX-Bus™ Modules Displayed
The XR200 Programmer includes a feature following the STOP routine that displays the name of any
programmed
LX-Bus module not currently connected to the panel. For example, if you had enabled any of the wireless options and
not yet installed a 472 HARD-WIRE-LESS Card, after the STOP routine the panel would display NO WIRELESS CARD.
This is a helpful reminder to install the card. This feature can also be a troubleshooting tool that could indicate a
problem if you
had
installed the card and still saw this message displayed. The following list shows the different
messages and their associated LX-Bus cards.
Keypad Display Missing Card
NO LXBUS CARD 481 LX-Bus™ Expansion Card
NO WIRELESS CARD 472 HARD-WIRE-LESS™ Card
NO PRINTER CARD 462P Printer Interface Card
NO DNET CARD 462N Network Interface Card
NO HOST CARD 462N Network Interface Card (with HOST communication selected)
The above messages clear automatically from the keypad after a few moments.
15.1 SET LOCKOUT CODE
Pressing COMMAND at the STOP prompt displays SET LOCKOUT CODE. This allows you
to program a code that will then be required to gain access to the panel's internal
Programmer through the keypad. You can change this code at any time to any combination
of numbers from 3 to 5 digits long.
Once you have changed the code, it is important to write it down somewhere and store it in a
safe place. Lost Lockout Codes require the panel to be sent back to DMP for repair.
Lockout Code restriction
Do not set a Lockout Code higher than 65535.
SET LOCKOUT CODE
STOP
14 - STOP
15 - SET LOCKOUT CODE